GB-5700-6 Glassbreak detector,6m,lam
Partcode:
- V54535-F103-A200
The glassbreak-detector is specially developed for working on laminated glass area within a radius of 2 m under surveillance. The
glass break detector must be pasted at the pane of glass with glueset from LOCTITE (Accessories).
Attention: Glueset differs from the glue dedicated to GB-5100 and GB-5300
Because the glass-surface is not plane, a surveillance of structure-glass is not possible. Also it is not allowed to use the
glassbreak-detector on wired glass, because the wire netting is damping the mechanical oscillations.
The detectors can be used in combination with the interface unit, GB-5000-IN, in bigger installations where you have to consider
power consumption. It is possible to connect up to 20 detectors to one interface unit.
Secondary Packaging: 25 Units
Supply voltage
3 – 16 V DC
Current consumption
3.5 mA (6 VDC)
Current consumption, quiescent
˂1 µA (ca. 20 nA)
Cable length
6 m
Operating temperature
-25 ~ 70 °C
Reset voltage
Max. 1 V
Housing material
S-B
Housing protection
IP67
Environmental class
III
Approval
EN 50131-2-7-2, Grade 2
Quiescent current
˂1 µA (ca. 20 nA)