GB-5000-IN Relay-Interface for GB
Partcode:
- V54550-F112-A100
The Relay-Interface is needed, if the line doesn’t allow to connect glass break detectors. This could happen because of several
reasons: At series-technology, digital supervision or if the line-voltage is below 3 V.
As a connecting link between a glass break detector and the panel, the Relay-Interface can be connected at or in each loop because
of it’s floating relay-contact. The electronic is placed in a plastic case. It allows the lead-in of wire on three sides. The
housing-cover is monitored against unauthorized opening by a tamper-switch.
Secondary Packaging: 25 Units
Supply voltage
10 ~ 15 V DC
Current consumption
13.5 mA
Current consumption, quiescent
5 mA
Switching voltage
Max. 24 VDC
Switching current
Max. 200 mA
Operating temperature
30 °C ~ 60 °C
Contact resistance
5 Ω
Housing material
S-B, A-B-S
Environmental class
II
Approval
VdS Klasse B (pending)
EOL resistor
2.2 kΩ
Quiescent current
5 mA