Operating voltage
12 to 24 VAC/DC
Current consumption
8 mA in standby
Inputs
Exit button requests with delay. Two separate for code disable.
Outputs
Voltage-free relay contact, max. 1 A, 28 VDC.
Opening time
1–30 sec.
Operating temperature
-35 bis +55 °C
Environment
Indoor or outdoor use (IP54 design). In very exposed locations, use SH2 or SH1 rain cover.
Housing protection
IP54
Housing
Gegossenes Metall mit Tasten aus rostfreiem Edelstahl und Sicherheitsschloss
Colour
Blue
Dimensions (W x H x D)
80 x 140 x 40 (mm)
Weight
0.72kg (per unit)
Housing protection (EN 60529)
IP54 design
Housing material
Cast metal with stainless steel buttons and security lock
Code capacity
Two four-digit codes
Operation temperature
-35°C ~ +55°C