Operating voltage
12 to 24 VAC/DC
Current consumption
8 mA in standby
Inputs
Exit button requests with delay. Two separate for code disable.
Outputs
Voltage-free relay contact, max. 1 A, 28 VDC.
Opening time
1–30 sec.
Code capacity
Two four-digit codes
Environment
Indoor or outdoor use (IP54 design). In very exposed locations, use SH2 or SH1 rain cover.
Housing protection
IP54 design
Housing
Cast metal with stainless steel buttons and security lock.
Colour
Blue
Dimensions (W x H x D)
80 x 140 x 40 mm
Weight
0.72 kg
Operation temperature
-35 to +55 °C